from SCHILLING ENGINEERING the total fulfilment

Pharma Industry

Cleanroom System for Packaging of Medicinal Components

Articleno.: 3000.4.317

Cleanroom System Packaging of Medicinal Components
ISO-Cleanroom class 8 (US. Fed. Stand. cl. 100'000)

  • self-supporting, modular construction system
  • composite panel-wall fillings
  • extensive cleanroom windows
  • innovative sealing-clip-system
  • U15 ULPA high performed-filter-fan-module
  • LSG (laminated sheet glass)
  • fully integrated, flush mounted cleanroom lighting
  • fully integrated clean air-over-flowing grilles near the ground
  • fully integrated media supply
  • compact cleanroom-air-conditioning system
  • fully integrated regulation
1.4.4-F2

Microbiol. safety working bench 3-filter-system (1640mm)

Articleno.: 8004.5.452

Microbiological safety working bench in class II
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100)

  • dimensions: (W x D x H) 1640 x 875 x 2215 mm ± 20 mm
  • safety working bench in class II / DIN 12469
    3-filter-system 
  • for personal, product and procrastination protection
  • housing made of sheet steel; with base; coated with powder
  • vertical laminarflow
  • H14 HEPA high performed filter
  • segmented stainless steel working bench
  • el.-front door; all panels made of security glass
  • aerosol close in closed position
  • air velocity: 0,35 m/s ± 20%, adjustable
  • monitoring of air flow with optical and acoustical alarm
  • double lighting, 2 switchable power socket
  • table height 765 ± 20 mm
1.4.4-F1

Mikrobiol. safety working bench 2-filter-system (1640mm)

Articleno.: 8004.5.449

Microbiological safety working bench in class II
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100)

  • dimensions: (W x D x H) 1640 x 875 x 2215 mm ± 20 mm
  • safety working bench in class II / DIN 12469
    2-filter-system 
  • for personal, product and procrastination protection
  • housing made of sheet steel; with base; coated with powder
  • vertical laminarflow
  • H14 HEPA high performed filter
  • segmented stainless steel working bench
  • el.-front door; all panels made of security glass
  • aerosol close in closed position
  • air velocity: 0,35 m/s ± 20%, adjustable
  • monitoring of air flow with optical and acoustical alarm
  • double lighting, 2 switchable power socket
  • table height 765 ± 20 mm
1.4.3_F6

VF Workingbench VA (1290x650x1980mm)

Articleno.: 3000.4.386

Vertikalflow Workingbench System Stainless Steel
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100)

  • (W x D x H) 1290 x 650 x 1980 mm
  • frame coated with stainless steel
  • very quiet filter-fan-module  < 50 dB (A)
  • U15 ULPA high performed  filter
  • washable PU-prefilter cell G4
  • air velocity: 0,2 – 0,7 m/s, adjustable
  • easy maintenance
  • built-on cleanroom lighting
  • easy commissioning (plug and play)
  • clean air power ca. 1800 m³/h
1.4.3_F3

VF Workingbench AL (1330x720x2100mm)

Articleno.: 5001.4.133

Vertikalflow Workingbench AL
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100)

  • (W x D x H) 1330 x 720 x 2100 mm
  • compact construction
  • housing made of cleanroom-aluminium-profile system
  • integrated base
  • table board coated with melamin
  • area’s fillings on side panels made of plexiglas, back panel made of white composite panel
  • very quiet filter-fan-module  < 50 dB (A)
  • U15 ULPA high performed  filter
  • washable PU-prefilter cell G4
  • air velocity: 0,2 – 0,7 m/s, adjustable
  • integrated  air streamlining
  • easy maintenance
  • built-on cleanroom lighting
  • easy commissioning (plug and play)
  • clean air power ca. 1800 m³/h
  • table height 780 mm (sitting action)
  • table height 900 mm (standing action)
  • option: also in version with 2 parts
  • further options: Vertikalflow ME
  • customer specific dimensions on request
1.4.2_F9

VF Working Bench VA (1290x650x1200mm)

Articleno.: 5001.4.487

Cleanroom Verticalflow Bench System Stainless Steel
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100) 

  • (W x D x H)   1290 x 650 x 1200 mm
  • compact construction
  • frame coated with stainless steel
  • very quiet filter-fan-module  < 50 dB (A)
  • U15 ULPA high performed  filter
  • washable PU-V prefilter cell G4
  • air velocity: 0,2 –0,7 m/s, adjustable
  • easy maintenance
  • built-on cleanroom lighting
  • easy commissioning (plug and play)
  • clean air power ca. 1800 m³/h
  • height dimensions for standing or sitting actions
  • customer specific dimensions on request
1.4.2_F3

VF Working Bench ME (1260x650x1200mm)

Articleno.: 5000.4.046-100

Cleanroom Verticalflow Bench System Melamin
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100) 

  • (W x D x H)   1260 x 650 x 1200 mm
  • compact construction
  • frame coated with melamin
  • very quiet filter-fan-module  < 50 dB (A)
  • U15 ULPA high performed  filter
  • washable PU-V prefilter cell G4
  • air velocity: 0,2 –0,7 m/s, adjustable
  • easy maintenance
  • built-on cleanroom lighting
  • easy commissioning (plug and play)
  • clean air power ca. 1800 m³/h
  • height dimensions for standing or sitting actions
  • customer specific dimensions on request
1.4.1_F2

Horizontalflow (1260x900x650mm)

Articleno.: 5000.4.017

Cleanroom Horizontalflow Bench System Melamin
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100)

  • (W x D x H)   1260 x 900 x 650 mm
  • compact construction
  • frame coated with melamin
  • very quiet filter-fan-module  < 50 dB (A)
  • U15 ULPA high performed  filter
  • washable PU-prefilter cell G4
  • air velocity: 0,2 –0,7 m/s, adjustable
  • easy maintenance
  • built-on cleanroom lighting
  • easy commissioning (plug and play)

 

Cytostatics Laboratory

Articleno.: 3000.4.288

Cytostatics Laboratory
GMP-Cleanroom class A in C

  • modular construction system
  • composite panel- wall fillings
  • silicone-free sealing-clip-system
  • U15 ULPA high performed-filter-fan-module
  • GMP- conformant version with filter leak test equipment
  • fully integrated, flush mounted cleanroom lighting
  • on site plenum upper ceiling (concrete ceiling)  
  • fully integrated return air guidance
  • cyto-depression room systems
  • fully integrated exhaust air systems in EX-version
  • compact cleanroom-air conditioning system

 

1.1.2_F6

Cytostatics Laboratory

Articleno.: 3000.4.319

Cytostatics Laboratory
GMP-Cleanroom class A in D

  • modular construction system
  • composite panel- wall fillings
  • silicone-free sealing-clip-system
  • U15 ULPA high performed-filter-fan-module
  • GMP- conformant version with filter leak test equipment
  • fully integrated, flush mounted cleanroom lighting
  • on site plenum upper ceiling (concrete ceiling)  
  • fully integrated return air guidance
  • cyto-depression room systems
  • fully integrated exhaust air systems in EX-version
  • compact cleanroom-air conditioning system
  • isolator technology
1.1.1.2-F5

Cleanroom System for Blistering

Articleno.: 3000.4.278

Cleanroom System for Blistering
ISO-Cleanroom class 8 (US. Fed. Stand. cl. 100'000)

  • self-supporting, modular construction system
  • composite panel-wall fillings
  • extensive cleanroom windows
  • innovative sealing-clip-system
  • U15 ULPA high performed-filter-fan-module
  • fully integrated, flush mounted cleanroom lighting
  • fully integrated clean air-over-flowing grilles near the ground
  • fully integrated media supply
  • compact cleanroom-air-conditioning system
  • fully integrated regulation
Mietzelt

Cleanroom Rent-Tent

Articleno.: 5000.4.276-001

Cleanroom cabin ISO-Cleanroom class  5 - 8
(US. Fed. Stand. Kl. 100 - 100'000)

  • modular cleanroom cabin for simple assembly 
  • minienvironment made of cleanroom-PVC-film curtains,          partly with strip curtains
  • U15 ULPA high performed-laminarflow-module
  • integrated cleanroom lighting
  • over-flowing zones near the ground
  • Dimension: (WxDxH mm) 2030 x 1750 x 2820 mm) / interior height: 2500 mm
1.2.1-F5

Hollow body blowing machines manufacturing

Articleno.: 3000.4.282

Cleanroom System for Pharma-, Diagnostic-, Food-, Cosmetic-Packing
ISO-Cleanroom class 7 (US. Fed. Stand. cl. 10'000)

  • cleanroom cabin with fully integrated changing room for
    personal and material
  • integrated test and packing zone
  • minienvironment made of composite panel and plexiglas windowpanes, partly with cleanroom PVC-film curtains as soon as temperature resistant film curtains
  • U15 ULPA high performed -laminarflow-module
  • built-on cleanroom lighting
  • over-flowing zones near the ground
  • selective particle extraction system
  • tool change from above possible
  • flexible applicable, displaceable cleanroom cabin system
Kleinkabinen

Hollow body blowing machines manufacturing

Articleno.: 3000.4.196

Cleanroom System for Pharma-, Diagnostic-, Food-, Cosmetic-Packing
ISO-Cleanroom class 7 (US. Fed. Stand. cl. 10'000)

  • cleanroom cabin with fully integrated changing room for
    personal, material and sampling
  • integrated test and packing zone
  • minienvironment made of composite panel and plexiglas windowpanes, partly with cleanroom PVC-film curtains
  • U15 ULPA high performed -laminarflow-module
  • fully integrated cleanroom lighting
  • over-flowing zones near the ground
  • fully integrated extraction system
  • tool change from above possible
  • flexible applicable, displaceable cleanroom cabin system

Serum Production

Articleno.: 3000.4.056

Cleanroom System for Serum Production
GMP-Cleanroom class A, B, C, D

  • modular construction system
  • extensive cleanroom windows
  • silicone-free sealing-clip-system
  • U15 ULPA high performed-filter-fan-module
  • GMP- conformant version with equipment for filter leak test
  • fully integrated, flush mounted cleanroom lighting
  • fully integrated air circulation and return air guidance
  • fully integrated media supply
  • fully integrated regulation 
  • fully integrated monitoring system (flow-velocity, particle, temperature, humidity, pressure inside the room)

Pharmaceutical Production

Articleno.: 3000.4.132-01

Cleanroom System for Pharmaceutical Production
GMP-Cleanroom class B, C, D, E

  • modular construction system
  • stainless steel-wall fillings
  • extensive VSG-cleanroom windows
  • silicone-free sealing-clip-system
  • U15 ULPA high performed-filter-fan-module
  • GMP- conformant version with equipment for filter leak test
  • fully integrated, flush mounted cleanroom lighting
  • fully integrated air circulation and return air guidance
  • on site plenum upper ceiling (concrete ceiling)
  • fully integrated point suction systems in EX-version
  • fully integrated media supply
CleanSteriCell

Bio-Technology

Articleno.: 3000.4.132

Cleanroom System for Bio-Technology Lab
GMP-Cleanroom class B, C, D, E

  • modular construction system
  • extensive cleanroom windows
  • silicone-free sealing-clip-system
  • U15 ULPA high performed-filter-fan-module
  • GMP-conformant version with equipment for filter leak test
  • fully integrated, flush mounted cleanroom lighting
  • fully integrated air circulation and return air guidance
  • on site plenum upper ceiling (concrete ceiling)
  • compact cleanroom-air conditioning system
  • fully integrated lab-working bench equipments
  • fully integrated point suction systems in EX-version
  • material changing room / pass-throughs

Cytostatics Lab

Articleno.: 3000.4.151

Cytostatics Lab
GMP-Cleanroom class A, B, C, D, E

  • modular construction system
  • composite panel- wall fillings
  • silicone-free sealing-clip-system
  • U15 ULPA high performed-filter-fan-module
  • GMP- conformant version with equipment for filter leak test
  • fully integrated, flush mounted cleanroom lighting
  • on site plenum upper ceiling (concrete ceiling)
  • fully integrated return air guidance
  • cyto-depression room systems
  • fully integrated exhaust air systems in EX-version
  • compact cleanroom-air conditioning system

Clean Flow Cell

Articleno.: 3000.4.067

Cleanroom Sampling Cabin
Sampling (Pharma)
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100)

  • for personal and product protection
  • U15 ULPA high performed -laminarflow-module
  • solid side panel and back panel
  • inside entry area cleanroom-PVC-film curtain
  • over-flowing area above the ground gap of the curtains
  • over-flowing of contaminated process return air carried out with fully integrated wall panel module for returning air
  • safety differential pressure monitoring
  • integrated filter contamination display
  • GMP- conform version with equipment for filter leak test
  • built-on cleanroom lighting
Einhausungen

PVC-Strip Curtain

Cleanroom PVC-Strip Curtain

  • angular blind with curtain- mounting system
  • film thickness 2 mm
  • transparent, UV-resistant
  • with hang-up ears, bottom cutting edges
  • antistatic design

PVC-Film Curtain

Cleanroom PVC-Film Curtain

  • angular blind with curtain- adjustable rail
  • film thickness 0,5 mm
  • transparent, UV-resistant
  • top with roll guides, bottom shrink-wrapped lead-cord

 
Special Design

  • antistatic
  • orange, UV-absorbing
  • black, EX-version
  • with velcro mounting

 

Laminarflow Boxen

Laminarflow Module (1200x600x320mm)

Articleno.: 8002.5.335

Cleanroom Laminarflow Module
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100)
ISO-Cleanroom class 4 (US. Fed. Stand. cl. 10)

  • dim. (W x D x H) 1200 x 600 x 320 mm
  • U15 ULPA high performed filter (filtration efficiency 99,9995%)
  • washable PU-prefilter G4
  • easy filter change
  • very quiet version < 50 dB (A)
  • airflow max. 1900 m³/h during V max. = 0,7 m/s (adjustable)
Cart
cart items none

News

  • 04/19/2012

    OPTATEC Exhibition 2012

    Optatec LOGO

  • 02/29/2012

    Cleanroom System CleanSteriCell® 2012 - Safety in Laboratories und Pharmacies

  • 01/28/2012

    Hospital pharmacy – Cleanroom labs ensure safety

Address
SCHILLING ENGINEERING GmbH
Industriestr. 26
D-79793 Wutöschingen

Phone: +49 (0)7746 - 92 789-0
Fax: +49 (0)7746 - 92 789-80

info@SchillingEngineering.de



SCHILLING ENGINEERING Schweiz GmbH
Dorfstrasse 60
Postfach 35
CH-8219 Trasadingen

Phone.: +41 (0)52 - 212 789-0
Fax: +41 (0)52 - 212 789-2

info@SchillingEngineering.ch