from SCHILLING ENGINEERING the total fulfilment

Microtechnology

1.4.3_F3

VF Workingbench AL (1330x720x2100mm)

Articleno.: 5001.4.133

Vertikalflow Workingbench AL
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100)

  • (W x D x H) 1330 x 720 x 2100 mm
  • compact construction
  • housing made of cleanroom-aluminium-profile system
  • integrated base
  • table board coated with melamin
  • area’s fillings on side panels made of plexiglas, back panel made of white composite panel
  • very quiet filter-fan-module  < 50 dB (A)
  • U15 ULPA high performed  filter
  • washable PU-prefilter cell G4
  • air velocity: 0,2 – 0,7 m/s, adjustable
  • integrated  air streamlining
  • easy maintenance
  • built-on cleanroom lighting
  • easy commissioning (plug and play)
  • clean air power ca. 1800 m³/h
  • table height 780 mm (sitting action)
  • table height 900 mm (standing action)
  • option: also in version with 2 parts
  • further options: Vertikalflow ME
  • customer specific dimensions on request
1.4.2_F3

VF Working Bench ME (1260x650x1200mm)

Articleno.: 5000.4.046-100

Cleanroom Verticalflow Bench System Melamin
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100) 

  • (W x D x H)   1260 x 650 x 1200 mm
  • compact construction
  • frame coated with melamin
  • very quiet filter-fan-module  < 50 dB (A)
  • U15 ULPA high performed  filter
  • washable PU-V prefilter cell G4
  • air velocity: 0,2 –0,7 m/s, adjustable
  • easy maintenance
  • built-on cleanroom lighting
  • easy commissioning (plug and play)
  • clean air power ca. 1800 m³/h
  • height dimensions for standing or sitting actions
  • customer specific dimensions on request
1.4.1_F2

Horizontalflow (1260x900x650mm)

Articleno.: 5000.4.017

Cleanroom Horizontalflow Bench System Melamin
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100)

  • (W x D x H)   1260 x 900 x 650 mm
  • compact construction
  • frame coated with melamin
  • very quiet filter-fan-module  < 50 dB (A)
  • U15 ULPA high performed  filter
  • washable PU-prefilter cell G4
  • air velocity: 0,2 –0,7 m/s, adjustable
  • easy maintenance
  • built-on cleanroom lighting
  • easy commissioning (plug and play)

 

Mietzelt

Cleanroom Rent-Tent

Articleno.: 5000.4.276-001

Cleanroom cabin ISO-Cleanroom class  5 - 8
(US. Fed. Stand. Kl. 100 - 100'000)

  • modular cleanroom cabin for simple assembly 
  • minienvironment made of cleanroom-PVC-film curtains,          partly with strip curtains
  • U15 ULPA high performed-laminarflow-module
  • integrated cleanroom lighting
  • over-flowing zones near the ground
  • Dimension: (WxDxH mm) 2030 x 1750 x 2820 mm) / interior height: 2500 mm
Reinraumsysteme

Assembly of Micropumps

Articleno.: 3000.4.012

Cleanroom System for Assembly of Micropumps
ISO-Cleanroom class 7 (US. Fed. Stand. cl. 10'000)

  • self-supporting, modular construction system
  • composite panel-wall fillings
  • extensive cleanroom windows
  • innovative sealing system
  • H14 HEPA high performed-filter-fan-module
  • fully integrated, flush mounted cleanroom lighting
  • fully integrated clean air-over-flowing grilles near the ground
  • fully integrated media supply
  • fully integrated point suction systems
  • integrated changing rooms for personal and material
  • fully integrated regulation

Opticcomponent-Assembly

Articleno.: 3000.4.095-01

Cleanroom System for Opticcomponent-Assembly
ISO-Cleanroom class 7 (US. Fed. Stand. cl. 10'000)

  • modular construction system
  • composite panel- wall fillings
  • extensive cleanroom windows
  • silicone-free sealing system
  • H14 HEPA high performed-filter-fan-module
  • fully integrated, flush mounted cleanroom lighting
  • fully integrated air circulation and return air guidance inside the cleanroom walls (optimal cleanroom-purging)
  • on site plenum upper ceiling (concrete ceiling)
  • compact cleanroom-air conditioning system
  • changing rooms for personal or material / pass-through
  • fully integrated regulation

Robots-Revision

Articleno.: 5000.4.470-01

Cleanroom System CleanFlowCell RS
for Cleanroom Robots-Revision
ISO-Cleanroom class 6 (US. Fed. Stand. cl. 1'000)

  • grid- modular construction system
    (L x W) 4500 x 6000 mm
    (H) 3000 mm
  • plane, white wall panel
  • U15 ULPA high performed -laminarflow-module
  • fully integrated cleanroom lighting
  • cleanroom door with glass insert
1.1.1.1-F5

Semiconductor Production

Articleno.: 3000.4.153

Cleanroom System for Semiconductor Production
ISO-Cleanroom class 6 (US. Fed. Stand. cl. 1'000)

  • self-supporting, modular construction system
  • composite panel-wall fillings
  • extensive cleanroom windows
  • innovative sealing system
  • U15 ULPA high performed-filter-fan-module
  • fully integrated, flush mounted cleanroom lighting
  • fully integrated air circulation and return air guidance
  • fully integrated media supply
  • changing rooms for personal or material / cleanroom door
    with sensitive switch and mutual door interlocking
    control
  • fully integrated regulation
Einhausungen

PVC-Strip Curtain

Cleanroom PVC-Strip Curtain

  • angular blind with curtain- mounting system
  • film thickness 2 mm
  • transparent, UV-resistant
  • with hang-up ears, bottom cutting edges
  • antistatic design

PVC-Film Curtain

Cleanroom PVC-Film Curtain

  • angular blind with curtain- adjustable rail
  • film thickness 0,5 mm
  • transparent, UV-resistant
  • top with roll guides, bottom shrink-wrapped lead-cord

 
Special Design

  • antistatic
  • orange, UV-absorbing
  • black, EX-version
  • with velcro mounting

 

Laminarflow Boxen

Laminarflow Module (1200x600x320mm)

Articleno.: 8002.5.335

Cleanroom Laminarflow Module
ISO-Cleanroom class 5 (US. Fed. Stand. cl. 100)
ISO-Cleanroom class 4 (US. Fed. Stand. cl. 10)

  • dim. (W x D x H) 1200 x 600 x 320 mm
  • U15 ULPA high performed filter (filtration efficiency 99,9995%)
  • washable PU-prefilter G4
  • easy filter change
  • very quiet version < 50 dB (A)
  • airflow max. 1900 m³/h during V max. = 0,7 m/s (adjustable)

Semiconductor Production

Articleno.: 3000.4.314

Cleanroom System for Semiconductor Production
ISO-Cleanroom class 6 (US. Fed. Stand. cl. 1'000)

  • self-supporting, modular construction system
  • composite panel-wall fillings
  • extensive cleanroom windows
  • innovative sealing system
  • U15 ULPA high performed-filter-fan-module
  • fully integrated, flush mounted cleanroom lighting
  • fully integrated air circulation and return air guidance
  • fully integrated media supply
  • changing rooms for personal or material / cleanroom door
    with sensitive switch and mutual door interlocking
    control
  • fully integrated regulation
Address
SCHILLING ENGINEERING GmbH
Industriestr. 26
D-79793 Wutöschingen

Phone: +49 (0)7746 - 92 789-0
Fax: +49 (0)7746 - 92 789-80

info@SchillingEngineering.de



SCHILLING ENGINEERING Schweiz GmbH
Dorfstrasse 60
Postfach 35
CH-8219 Trasadingen

Phone.: +41 (0)52 - 212 789-0
Fax: +41 (0)52 - 212 789-2

info@SchillingEngineering.ch